Siemens SINUMERIK 840D sl Function Manual page 152

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

A3: Axis Monitoring, Protection Zones
3.3 Protection zones
<Dist>:
<Limit>:
152
Reference to a vector.
Input: Incremental traversing distance
● <Dist> [0]: Abscissa
● <Dist> [1]: Ordinate
● <Dist> [2]: Applicate
Output (only for set hundred thousands digit in <Status>):
<Dist> contains a unit vector v as output value which defines the further travers‐
ing direction in the WCS.
Case 1: Formation of vector v for <TestID>, bit 4 == 1
The input vectors <Dist> and <MaxDist> span the motion plane. This plane is
cut by the violated limitation surface. The intersecting line of the two planes
defines the direction of vector v. The orientation (sign) is selected so that the
angle between the input vector <MaxDist> and v is not greater than 90 degrees.
Case 2: Formation of vector v for <TestID>, bit 5 == 1
Vector v is the unit vector in the projection direction of the traversing vector
contained in <Dist> on the limitation surface. If the projection of the traversing
vector on the limitation surface is the zero vector, an error is returned.
Parameter type:
Input/output
Data type:
VAR REAL [3]
Range of values:
-max. REAL value ≤ x[n] ≤ +max. REAL value
Reference to an array of length 5.
● <Limit> [0 - 2]: Minimum clearance of the geometry axes to the limits:
<Limit> [0]: Abscissa
<Limit> [1]: Ordinate
<Limit> [2]: Applicate
The minimum clearances are observed with:
Working area limitation: No restrictions
Software limit switch: If no transformation is active, or a transformation is
active in which a clear assignment of the geometry axes to the linear machine
axes is possible, e.g. 5-axis transformations.
● <Limit> [3]: Contains the minimum clearance for linear machine axes which, for
example, cannot be assigned a geometry axis because of a non-linear
transformation. This value is also used as limit value for the monitoring of the
conventional protection zones and the collision avoidance protection zones.
● <Limit> [4]: Contains the minimum clearance for rotary machine axes which, for
example, cannot be assigned a geometry axis because of a non-linear
transformation.
Note
This value is only active for the monitoring of the software limit switches for special
transformations.
Parameter type:
Input
Data type:
VAR REAL [5]
Range of values:
-max. REAL value ≤ x[n] ≤ +max. REAL value
Function Manual, 01/2015, 6FC5397-0BP40-5BA2
Basic Functions