User-Specific Asub For Ret And Repos; Function; Parameter Assignment - Siemens SINUMERIK 840D sl Function Manual

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

3. Assign the HW input byte to the SETINT interrupt programming:
– Input byte 2:
4. Define input as ASUB trigger:
– Input 1 in the second input byte, i.e. absolute input 9, starts SYNCASUP program
5. Define a synchronized action to set the output:
– Synchronized action with ID 1 always sets output 9 to 1 when the value of the
9.11

User-specific ASUB for RET and REPOS

9.11.1

Function

Function
The NCK software supplied contains preprogrammed processes (internal ASUBs) for
implementation of the RET and REPOS functions. They can be replaced by user-specific
ASUBs written by the machine tool manufacturer.
Programming fault
The machine manufacturer is responsible for the contents of ASUB routines used to replace
ASUP.SYF supplied by Siemens.
Installation
In the manufacturer directory _N_CMA_DIR or in the user directory _N_CUS_DIR a routine
with the name "_N_ASUP_SPF" can be loaded. It must implement the actions desired by the
user for the functions RET and REPOS.
9.11.2

Parameter assignment

Activation
The parameters for the activation of the user-specific routine "_N_ASUP_SPF" are set with the
machine data:
MD11610 $MN_ASUP_EDITABLE (activation of a user-specific ASUB).
Basic Functions
Function Manual, 01/2015, 6FC5397-0BP40-5BA2
MD21210 $MC_SETINT_ASSIGN_FASTIN = 2
SETINT(1) PRIO=1 SYNCASUP
standardized path parameter becomes >= 0.5:
IDS=1 EVERY $$AC_PATHN >= 0.5 DO $A_OUT_[9]=1
DANGER
K1: Mode group, channel, program operation, reset response
9.11 User-specific ASUB for RET and REPOS
571

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 828dSinumerik 840de sl

Table of Contents