END_VAR
Description of formal parameters of SINUMERIK 840D sl
Signal
MCPNum:
MCP1In:
MCP2In:
MCP1Out:
MCP2Out:
MCP1StatSend:
MCP2StatSend:
MCP1StatRec:
MCP2StatRec:
MCP1BusAdr:
MCP2BusAdr:
MCP1Timeout:
MCP2Timeout:
MCP1Cycl:
MCP2Cycl:
MCPMPI:
MCP1Stop:
MCP2Stop:
Basic Functions
Function Manual, 01/2015, 6FC5397-0BP40-5BA2
ActivAxis:
ARRAY[1..31] OF
BOOL;
UDInt :
INT;
UDHex:
INT;
UDReal :
INT;
IdentMcpType :
BYTE ;
IdentMcpLengthIn : BYTE ;
IdentMcpLengthOut
BYTE ;
:
Typ
Type
e
I
INT
I
POINTER
I
POINTER
I
POINTER
I
POINTER
I
INT
I
S5time
I
S5time
I
BOOL
I
BOOL
P3: Basic PLC program for SINUMERIK 840D sl
Value range
0, 1, 2
E0.0 ... E120.0
or
M0.0 ... M248.0
or
DBn DBX0.0 ... DBXm.0
A0.0 ... A120.0
or
M0.0 ... M248.0
or
DBn DBX0.0 ... DBXm.0
A0.0 ... A124.0
or
M0.0 ... M252.0
or
DBn DBX0.0 ... DBXm.0
A0.0 ... A124.0
or
M0.0 ... M252.0
or
DBn DBX0.0 ... DBXm.0
1, 2, 3 ... 126
192, 193, 194 .. 223
Recommendation: 700 ms
Recommendation: 200 ms
FALSE
0 (FALSE), 1 (TRUE)
13.17 Block descriptions
Description
Number of active MCPs
0: No MCPs available
Start address for input signals of relevant
machine control panel
Start address for output signals of relevant
machine control panel
Only for Ethernet MCP:
Switch off flashing (see Section "Switch‐
over of machine control panel, handheld
unit (Page 876)")
Currently no significance
DP slave: PROFIBUS address
Ethernet MCP: DIP setting
Cyclic sign-of-life monitoring for machine
control panel
Relevant only for PROFIBUS
Available owing to compatibility
0: Start transfer of machine control panel
signals
1: Stop transfer of machine control panel
signals
DP slave: Slave deactivated