10.4 Coordinate systems
10.4.6

Settable zero system (SZS)

Settable zero system (SZS)
The "settable zero system" (SZS) is the workpiece coordinate system WCS with a
programmable frame (viewed from the perspective of the WCS). The workpiece zero is defined
by the settable FRAMES G54 to G599.
Figure 10-18 Settable FRAME G54 ... G599 between BNS and ENS
Programmable offsets act on the "settable zero system". All programmable offsets refer to the
"settable zero system".
WCS actual-value display in WCS or SZS
The actual values of the axes in the machine coordinate system (MCS) or the WCS can be
displayed on the HMI operator interface. For displays in WCS, the actual values can also be
displayed in relation to the SZS. The corresponding parameterization takes place through the
machine data:
MD9424 $MM_MA_COORDINATE_SYSTEM (coordinate system for actual value display)
Value
0
1
702
Significance
Actual-value display in relation to the WCS
Actual-value display in relation to the SZS
Function Manual, 01/2015, 6FC5397-0BP40-5BA2