Defaults
The following default passwords are defined for protection levels 1 to 3:
● Protection level 1: SUNRISE
● Protection level 2: EVENING
● Protection level 3: CUSTOMER
Note
Following NC-CPU ramp-up in commissioning mode (NCK commissioning switch: position
1) the passwords for protection levels 1 – 3 are reset to the default settings. For reasons
of data protection, we strongly recommend that you change the default settings.
2.3.5.2

Keyswitch positions (DB10, DBX56.4 to 7)

Key switch
The keyswitch has four positions, to which protection levels 4 to 7 are assigned. The keyswitch
comprises a number of keys in a variety of colors which can be set to different switch positions.
Figure 2-10
Switch positions
Switch position 0 has the most restricted access rights. Switch position 3 has the least restricted
access rights.
DB10, DBX56.4 / .5 / .6 / .7 (switch positions 0 / 1 / 2 / 3)
Machine-specific enables for access to programs, data and functions can be assigned to the
switch positions. For detailed information, please refer to:
Basic Functions
Function Manual, 01/2015, 6FC5397-0BP40-5BA2
Switch positions 0 to 3
A2: Various NC/PLC interface signals and functions
2.3 Functions
63