Signal
BHGSendGDNo:
BHGSendGBZNo:
BHGSendObjNo:
BHGMPI:
BHGStop:
BHGNotSend:
NCCyclTimeout:
NCRunupTimeout:
ListMDecGrp:
NCKomm:
MMCToIF:
HWheelMMC:
ExtendAlMsg :
MsgUser:
UserIR:
IRAuxfuT:
IRAuxfuH:
IRAuxfuE:
UserVersion:
Basic Functions
Function Manual, 01/2015, 6FC5397-0BP40-5BA2
Typ
Type
e
I
INT
I
Int
I
INT
I
BOOL
I
BOOL
I
BOOL
I
S5time
Recommendation: 200 ms
I
S5time
I
INT
I
BOOL
I
BOOL
I
BOOL
I
BOOL
I
INT
I
BOOL
I
BOOL
I
BOOL
I
BOOL
I
POINTER
P3: Basic PLC program for SINUMERIK 840D sl
Value range
HHU default: 2
HHU default: 1
HHU default: 1
0 (FALSE)
0 (FALSE), 1 (TRUE)
0 (FALSE), 1 (TRUE)
Recommendation: 50 s
0, 1, 2 ... 16
0 (FALSE), 1 (TRUE)
0 (FALSE), 1 (TRUE)
0 (FALSE), 1 (TRUE)
0 (FALSE), 1 (TRUE)
0, 1, 2 ... 64
0 (FALSE), 1 (TRUE)
0 (FALSE), 1 (TRUE)
0 (FALSE), 1 (TRUE)
0 (FALSE), 1 (TRUE)
P#DBn.DBXx.0
13.17 Block descriptions
Description
Available owing to compatibility
Available owing to compatibility
Available owing to compatibility
Available owing to compatibility
0: Start transmission of handheld unit sig‐
nals
1: Stop transmission of handheld unit sig‐
nals
0: Send and receive operation activated
1: Receive handheld unit signals only
Cyclic sign-of-life monitoring NCK
Power-up monitoring NCK
Activation of expanded M group decoding
0: Not active
1...16: Number of M groups
PLC NC communication services FB2, 3,
4, 5, 7
1: Active
Transmission of HMI signals to interface
(modes, program control etc.)
1: Active
0: Handwheel selection via HMI
1: Handwheel selection via user program
Activation of extensions error and operat‐
ing messages of the FC10 (see section
"Extensions of the PLC alarms via block
FC10" in Chapter "Interface PLC/HMI
(Page 842)")
Number of user areas (DB2) – depends on
parameter "ExtendAIMsg"
Local data expansion OB40 required for
processing of signals from the user
Evaluate T function in OB40
Evaluate H function in OB40
Evaluate DL function in OB40
Pointer to string variable, which is dis‐
played in the version display of the user
interface
The following written format applies to the
string variable (max. 41 characters:
"<"<Name> <Version xx.xx.xx> <Date yy/
mm/dd>"
Example: "Test-Version 07.06.02
13/06/04"