MD27860 $MC_PROCESSTIMER_MODE, bit 0 - 2 = <value>
Bit
0
1
2
Parameterization
Behavior of the timer that is always active
The behavior of the timer that is always active for GOTOS and override = 0% is set using
machine data:
MD27850 $MC_PROG_NET_TIMER_MODE
Bit
0
1
Behavior of the timer that can be activated
The behavior of the timer that can be activated for certain functions (e.g. test run feedrate,
program test) is set using machine data:
MD27860 $MC_PROCESSTIMER_MODE
Bit
4
5
6
Basic Functions
Function Manual, 01/2015, 6FC5397-0BP40-5BA2
Value
Meaning
0
Timer for $AC_OPERATING_TIME not active.
1
Timer for $AC_OPERATING_TIME active.
0
Timer for $AC_CYCLE_TIME not active.
1
Timer for $AC_CYCLE_TIME active.
0
Timer for $AC_CUTTING_TIME not active.
1
Timer for $AC_CUTTING_TIME active.
Value
Meaning
0
$AC_ACT_PROG_NET_TIME is not reset to "0" in case of a jump with GOTOS to the
program start (initial setting).
1
With a jump with GOTOS to the start of the program, $AC_ACT_PROG_NET_TIME is
reset to "0", the value is first saved in $AC_OLD_PROG_NET_TIME and the program
counter $AC_OLD_PROG_NET_TIME_COUNT is incremented.
0
For override = 0%, $AC_ACT_PROG_NET_TIME is not increased. This means that the
program runtime is measured without the time for which the override was set to "0"
(basic setting).
1
Also for override = 0%, $AC_ACT_PROG_NET_TIME is increased. This means that
the program runtime is measured with the time for which the override was set to "0".
Value
Meaning
0
No measurement during active dry run feedrate.
1
Measurement during active dry run feedrate.
0
No measurement during program test.
1
Measurement during program test.
Only for bit 1 = 1 (timer for $AC_CYCLE_TIME is active)
0
$AC_CYCLE_TIME is reset to "0" also in case of Start through ASUB and
PROG_EVENTs.
1
$AC_CYCLE_TIME is not reset to "0" in case of Start through ASUB and
PROG_EVENTs.