Output behavior for which parameters have been assigned:
MD22200 $MC_AUXFU_M_SYNC_TYPE = 1
MD22220 $MC_AUXFU_T_SYNC_TYPE = 0
MD22230 $MC_AUXFU_H_SYNC_TYPE = 2
Parts program block:
Program code
...
N10 G01 X100 M07 H5 T5
...
Time sequence for auxiliary function output:
8.6
Priorities of the output behavior for which parameters have been
assigned
The following priorities must be observed for the following areas in connection with the
parameterized output behavior of an auxiliary function:
● Output duration (normal / quick acknowledgement)
● Output relative to motion (prior to / during / after the motion)
As a general rule, the parameterized output behavior with lower priority becomes active if no
output behavior with higher priority has been parameterized.
Basic Functions
Function Manual, 01/2015, 6FC5397-0BP40-5BA2
8.6 Priorities of the output behavior for which parameters have been assigned
H2: Auxiliary function outputs to PLC
⇒
M function:
Output during motion
⇒
T function:
Output prior to motion
⇒
H function:
Output at the end of the block