Product overview

3.1

New functions

New functions of the SIMATIC Drive Controller in firmware version V3.0
The following table provides an overview of the important new functions of the SIMATIC
Drive Controller with CPU firmware V3.0 and SINAMICS Integrated firmware V5.2 SP3.
New functions
Communication of the CPU
Network management pro­
tocol SNMP
OPC UA server – Reading the
diagnostics status of the own
address space
OPC UA server – Time stamp­
ing of the source time of
nodes
OPC UA server – Increased
configuration limits
Web server of the CPU
New Web API methods
Dynamic management of cer­
tificates
SIMATIC Drive Controller
Equipment Manual, 11/2022, A5E46600370-AC
Applications
A simple configuration option is now available
for using SNMP services. For new configura­
tions, this is disabled by default in line with
"Security-by-Default".
The own namespace of the OPC UA server can
be accessed by using the OPC UA instruction for
reading ("OPC_UA_ReadList").
This allows you to read out the following status
and react to it in the user program:
Status of the own OPC UA server
Status of the connections of OPC UA clients
Status of the session
Status of subscriptions
By using the OPC UA instruction for writing
("OPC_UA_WriteList"), it is possible to change
the "SourceTimestamp" as well as the status
code of an OPC UA variable (node).
The following configuration limits have been
increased:
Possible number of nodes in the server
interface
Maximum possible number of subscriptions
per session
For subscription, the recommendation for
monitored values was increased
Many new API methods expand your access
options to the CPU via the Web API.
The Web server certificate for HTTPS commu­
nication can now also be managed via the OPC
UA GDS mechanism, without separate down­
load of the hardware configuration.
Customer benefits
Simpler configuration
This allows connection problems to be
quickly detected, for example, and plant
availability to be increased.
Distinction between the "source" and "server"
time possible
Further applications for CPUs as OPC UA serv­
ers
Additional applications for the Web server
Flexible certificate management
3