Danfoss VLT FC 103 Programming Manual page 13

Refrigeration drive
Hide thumbs Also See for VLT FC 103:
Table of Contents

Advertisement

How to Programme
The Bottom section (c) always shows the state of the
frequency converter in Status mode.
2
2
It is possible to toggle between three status read-out
displays by pressing the [Status] key.
Operating variables with different formatting are shown in
each status screen - see below.
Several values or measurements can be linked to each of
the displayed operating variables. The values /
measurements to be displayed can be defined via
0-20 Display Line 1.1 Small, 0-21 Display Line 1.2 Small,
0-22 Display Line 1.3 Small, 0-23 Display Line 2 Large and
0-24 Display Line 3 Large, which can be accessed via [QUICK
MENU], "Q3 Function Setups", "Q3-1 General Settings",
"Q3-13 Display Settings".
Each value/measurement readout parameter selected in
0-20 Display Line 1.1 Small to 0-24 Display Line 3 Large has
its own scale and number of digits after a possible decimal
point. Larger numeric values are displayed with few digits
after the decimal point.
Ex.: Current readout
5.25 A; 15.2 A 105 A.
Status display I
This read-out state is standard after start-up or initiali-
sation.
Use [INFO] to obtain information about the value/
measurement linked to the displayed operating variables
(1.1, 1.2, 1.3, 2, and 3).
See the operating variables shown in the display in this
illustration. 1.1, 1.2 and 1.3 are shown in small size. 2 and
3 are shown in medium size.
1.1
1.2
Illustration 2.2
Status display II
See the operating variables (1.1, 1.2, 1.3, and 2) shown in
the display in this illustration.
In the example, Speed, Motor current, Motor power and
Frequency are selected as variables in the first and second
lines.
1.1, 1.2 and 1.3 are shown in small size. 2 is shown in large
size.
12
Status
799 RPM
7.83 A
0.000
53.2 %
Auto Remote Ramping
2
3
1.3
MG16H102 - VLT
®
VLT
Refrigeration Drive Programming Guide
Illustration 2.3
Status display III
This state displays the event and action of the Smart Logic
Control. For further information, see .
Illustration 2.4
Display Contrast Adjustment
Press [status] and [
Press [status] and [
Top section
1 (1)
Middle section
36.4 kw
Bottom section
Illustration 2.5
Indicator lights (LEDs)
If certain threshold values are exceeded, the alarm and/or
warning LED lights up. A status and alarm text appear on
the control panel.
The On LED is activated when the frequency converter
receives power from mains voltage, a DC bus terminal, or
an external 24V supply. At the same time, the back light is
on.
®
is a registered Danfoss trademark
Status
207RPM
5.25A
1.1
6.9
Hz
Auto Remote Running
Status
778 RPM
0.86 A
State: 0 o 0 (o )
When: -
Do: -
Auto Remote Running
] for darker display
] for brighter display
Status
43 RPM
5.44 A
1.4 Hz
2.9%
! Pwr.card temp (W29)
Auto Remote Running
1 (1)
24.4 kW
1.3
1.2
2
1 (1)
4.0 kW
!
1(1)
25.3kW