Parameter Lists

4.1.6 4-** Limits/Warnings

Par. No. #
Parameter description
4-1* Motor Limits
4-10
Motor Speed Direction
4-11
Motor Speed Low Limit [RPM]
4
4
4-12
Motor Speed Low Limit [Hz]
4-13
Motor Speed High Limit [RPM]
4-14
Motor Speed High Limit [Hz]
4-16
Torque Limit Motor Mode
4-17
Torque Limit Generator Mode
4-18
Current Limit
4-19
Max Output Frequency
4-5* Adj. Warnings
4-50
Warning Current Low
4-51
Warning Current High
4-52
Warning Speed Low
4-53
Warning Speed High
4-54
Warning Reference Low
4-55
Warning Reference High
4-56
Warning Feedback Low
4-57
Warning Feedback High
4-58
Missing Motor Phase Function
4-6* Speed Bypass
4-60
Bypass Speed From [RPM]
4-61
Bypass Speed From [Hz]
4-62
Bypass Speed To [RPM]
4-63
Bypass Speed To [Hz]
4-64
Semi-Auto Bypass Set-up
Table 4.7

4.1.7 5-** Digital In/Out

Par. No. # Parameter description
5-0* Digital I/O mode
5-00
Digital I/O Mode
5-01
Terminal 27 Mode
5-02
Terminal 29 Mode
5-1* Digital Inputs
5-10
Terminal 18 Digital Input
5-11
Terminal 19 Digital Input
5-12
Terminal 27 Digital Input
5-13
Terminal 29 Digital Input
5-14
Terminal 32 Digital Input
5-15
Terminal 33 Digital Input
5-16
Terminal X30/2 Digital Input
172
®
VLT
Refrigeration Drive Programming Guide
Default value
4-set-up
[0] Clockwise
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
110 %
All set-ups
100 %
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
0 A
All set-ups
ImaxVLT (P1637)
All set-ups
0 RPM
All set-ups
outputSpeedHighLimit
(P413)
All set-ups
-999999 N/A
All set-ups
999999 N/A
All set-ups
-999999 ReferenceFeed-
backUnit
All set-ups
999999 ReferenceFeed-
backUnit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
[0] Off
All set-ups
Default value
4-set-up
[0] PNP - Active at 24V
All set-ups
[0] Input
All set-ups
[0] Input
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
®
MG16H102 - VLT
is a registered Danfoss trademark
Change
Conver-
during
sion index
operation
FALSE
-
TRUE
67
TRUE
-1
TRUE
67
TRUE
-1
TRUE
-1
TRUE
-1
TRUE
-1
FALSE
-1
TRUE
-2
TRUE
-2
TRUE
67
TRUE
67
TRUE
-3
TRUE
-3
TRUE
-3
TRUE
-3
TRUE
-
TRUE
67
TRUE
-1
TRUE
67
TRUE
-1
FALSE
-
Change
Conver-
during
sion index
operation
FALSE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
Type
Uint8
Uint16
Uint16
Uint16
Uint16
Uint16
Uint16
Uint32
Uint16
Uint32
Uint32
Uint16
Uint16
Int32
Int32
Int32
Int32
Uint8
Uint16
Uint16
Uint16
Uint16
Uint8
Type
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8

Advertisement

Table of Contents
loading

Table of Contents