Pack Controller - Danfoss VLT FC 103 Programming Manual

Refrigeration drive
Hide thumbs Also See for VLT FC 103:
Table of Contents

Advertisement

Parameter Lists
Par. No. # Parameter description
23-16
Maintenance Text
23-5* Energy Log
23-50
Energy Log Resolution
23-51
Period Start
23-53
Energy Log
23-54
Reset Energy Log
23-6* Trending
23-60
Trend Variable
23-61
Continuous Bin Data
23-62
Timed Bin Data
23-63
Timed Period Start
23-64
Timed Period Stop
23-65
Minimum Bin Value
23-66
Reset Continuous Bin Data
23-67
Reset Timed Bin Data
23-8* Payback Counter
23-80
Power Reference Factor
23-81
Energy Cost
23-82
Investment
23-83
Energy Savings
23-84
Cost Savings
Table 4.20

4.1.20 25-** Pack Controller

Par. No. #
Parameter description
25-0* System Settings
25-00
Pack Controller
25-04
Compressor Cycling
25-06
Number of Compressors
25-2* Zone Settings
25-20
Neutral Zone [unit]
25-21
+ Zone [unit]
25-22
- Zone [unit]
25-23
Fixed Speed neutral Zone [unit]
25-24
+ Zone Delay
25-25
- Zone Delay
25-26
++ Zone Delay
25-27
-- Zone Delay
25-3* Staging Functions
25-30
Destage At No-Flow
25-31
Stage Function
25-32
Stage Function Time
25-33
Destage Function
®
VLT
Refrigeration Drive Programming Guide
Default value
4-set-up
0 N/A
[5] Last 24 Hours
2 set-ups
ExpressionLimit
2 set-ups
0 N/A
All set-ups
[0] Do not reset
All set-ups
[0] Power [kW]
2 set-ups
0 N/A
All set-ups
0 N/A
All set-ups
ExpressionLimit
2 set-ups
ExpressionLimit
2 set-ups
ExpressionLimit
2 set-ups
[0] Do not reset
All set-ups
[0] Do not reset
All set-ups
100 %
2 set-ups
1 N/A
2 set-ups
0 N/A
2 set-ups
0 kWh
All set-ups
0 N/A
All set-ups
Default value
4-set-up
[0] Disabled
2 set-ups
[0] Disabled
All set-ups
2 N/A
2 set-ups
4 ReferenceFeed-
backUnit
All set-ups
3 ReferenceFeed-
backUnit
All set-ups
3 ReferenceFeed-
backUnit
All set-ups
4 ReferenceFeed-
backUnit
All set-ups
120 s
All set-ups
60 s
All set-ups
60 s
All set-ups
30 s
All set-ups
[0] Disabled
All set-ups
[0] Disabled
All set-ups
15 s
All set-ups
[0] Disabled
All set-ups
®
MG16H102 - VLT
is a registered Danfoss trademark
Change
during
sion index
operation
1 set-up
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
Change
during
sion index
operation
FALSE
TRUE
FALSE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
Conver-
Type
0
VisStr[20]
-
Uint8
0
TimeOfDay
0
Uint32
-
Uint8
-
Uint8
0
Uint32
0
Uint32
0
TimeOfDay
0
TimeOfDay
0
Uint8
-
Uint8
-
Uint8
0
Uint8
-2
Uint32
0
Uint32
75
Int32
0
Int32
Conver-
Type
-
Uint8
-
Uint8
0
Uint8
-2
Uint32
-2
Uint32
-2
Uint32
-2
Uint32
0
Uint32
0
Uint32
0
Uint32
0
Uint32
-
Uint8
-
Uint8
0
Uint16
-
Uint8
185
4
4

Advertisement

Table of Contents
loading

Table of Contents