Fc Closed Loop - Danfoss VLT FC 103 Programming Manual

Refrigeration drive
Hide thumbs Also See for VLT FC 103:
Table of Contents

Advertisement

Parameter Lists
Par. No. # Parameter description
18-33
Analog Out X42/7 [V]
18-34
Analog Out X42/9 [V]
18-35
Analog Out X42/11 [V]
Table 4.16

4.1.16 20-** FC Closed Loop

Par. No. # Parameter description
20-0* Feedback
20-00
Feedback 1 Source
20-01
Feedback 1 Conversion
20-02
Feedback 1 Source Unit
20-03
Feedback 2 Source
20-04
Feedback 2 Conversion
20-05
Feedback 2 Source Unit
20-06
Feedback 3 Source
20-07
Feedback 3 Conversion
20-08
Feedback 3 Source Unit
20-12
Reference/Feedback Unit
20-2* Feedback/Setpoint
20-20
Feedback Function
20-21
Setpoint 1
20-22
Setpoint 2
20-23
Setpoint 3
20-25
Setpoint Type
20-3* Feedback Adv. Conv
20-30
Refrigerant
20-31
User Defined Refrigerant A1
20-32
User Defined Refrigerant A2
20-33
User Defined Refrigerant A3
20-4* Thermostat/Pressostat
20-40
Thermostat/Pressostat Function
20-41
Cut-out Value
20-42
Cut-in Value
20-7* PID Autotuning
20-70
Closed Loop Type
20-71
PID Performance
20-72
PID Output Change
20-73
Minimum Feedback Level
20-74
Maximum Feedback Level
20-79
PID Autotuning
20-8* PID Basic Settings
20-81
PID Normal/ Inverse Control
20-82
PID Start Speed [RPM]
20-83
PID Start Speed [Hz]
20-84
On Reference Bandwidth
20-9* PID Controller
®
VLT
Refrigeration Drive Programming Guide
Default value
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
Default value
4-set-up
[2] Analog Input 54
All set-ups
[2] Pressure to
temperature
All set-ups
ExpressionLimit
All set-ups
[0] No function
All set-ups
[0] Linear
All set-ups
ExpressionLimit
All set-ups
[0] No function
All set-ups
[0] Linear
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
[3] Minimum
All set-ups
0 ProcessCtrlUnit
All set-ups
0 ProcessCtrlUnit
All set-ups
0 ProcessCtrlUnit
All set-ups
ExpressionLimit
All set-ups
[19] R404A
All set-ups
10 N/A
All set-ups
-2250 N/A
All set-ups
250 N/A
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
[0] Auto
2 set-ups
[0] Normal
2 set-ups
0.10 N/A
2 set-ups
-999999 ProcessCtrlUnit
2 set-ups
999999 ProcessCtrlUnit
2 set-ups
[0] Disabled
All set-ups
[1] Inverse
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
5 %
All set-ups
®
MG16H102 - VLT
is a registered Danfoss trademark
4-set-up
Change
Conver-
during
sion index
operation
FALSE
FALSE
FALSE
Change
Conver-
during
sion index
operation
TRUE
FALSE
TRUE
TRUE
FALSE
TRUE
TRUE
FALSE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
Type
-3
Int16
-3
Int16
-3
Int16
Type
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-3
Int32
-3
Int32
-3
Int32
-
Uint8
-
Uint8
-4
Uint32
-2
Int32
-3
Uint32
-
Uint8
-3
Int32
-3
Int32
-
Uint8
-
Uint8
-2
Uint16
-3
Int32
-3
Int32
-
Uint8
-
Uint8
67
Uint16
-1
Uint16
0
Uint8
181
4
4

Advertisement

Table of Contents
loading

Table of Contents