Parameter Lists
Par. No. # Parameter description
1-6* Load Depen. Setting
1-60
Low Speed Load Compensation
1-61
High Speed Load Compensation
1-62
Slip Compensation
1-63
Slip Compensation Time Constant
4
4
1-64
Resonance Dampening
Resonance Dampening Time
1-65
Constant
1-66
Min. Current at Low Speed
1-7* Start Adjustments
1-70
PM Start Mode
1-71
Start Delay
1-72
Start Function
1-73
Flying Start
1-74
Start Speed [RPM]
1-75
Start Speed [Hz]
1-76
Start Current
Compressor Start Max Speed
1-77
[RPM]
1-78
Compressor Start Max Speed [Hz]
Compressor Start Max Time to
1-79
Trip
1-8* Stop Adjustments
1-80
Function at Stop
Min Speed for Function at Stop
1-81
[RPM]
Min Speed for Function at Stop
1-82
[Hz]
Compressor Min. Speed for Trip
1-86
[RPM]
Compressor Min. Speed for Trip
1-87
[Hz]
1-9* Motor Temperature
1-90
Motor Thermal Protection
1-91
Motor External Fan
1-93
Thermistor Source
Table 4.4

4.1.4 2-** Brakes

Par. No. #
Parameter description
2-0* DC-Brake
2-00
DC Hold/Preheat Current
2-01
DC Brake Current
2-02
DC Braking Time
2-03
DC Brake Cut In Speed [RPM]
2-04
DC Brake Cut In Speed [Hz]
2-06
Parking Current
2-07
Parking Time
170
®
VLT
Refrigeration Drive Programming Guide
Default value
4-set-up
100 %
All set-ups
100 %
All set-ups
0 %
All set-ups
ExpressionLimit
All set-ups
100 %
All set-ups
5 ms
All set-ups
ExpressionLimit
All set-ups
[1] Parking
All set-ups
00 s
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
0 A
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
5 s
All set-ups
[0] Coast
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
[0] None
All set-ups
[0] None
All set-ups
Default value
4-set-up
50 %
All set-ups
50 %
All set-ups
10 s
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
50 %
All set-ups
3 s
All set-ups
®
MG16H102 - VLT
is a registered Danfoss trademark
Change
Conver-
during
sion index
operation
TRUE
0
TRUE
0
TRUE
0
TRUE
-2
TRUE
0
TRUE
-3
TRUE
0
TRUE
-
TRUE
-1
TRUE
-
FALSE
-
TRUE
67
TRUE
-1
TRUE
-2
TRUE
67
TRUE
-1
TRUE
-1
TRUE
-
TRUE
67
TRUE
-1
TRUE
67
TRUE
-1
TRUE
-
TRUE
-
TRUE
-
Change
Conver-
during
sion index
operation
TRUE
0
TRUE
0
TRUE
-1
TRUE
67
TRUE
-1
TRUE
0
TRUE
-1
Type
Int16
Int16
Int16
Uint16
Uint16
Uint8
Uint8
Uint8
Uint16
Uint8
Uint8
Uint16
Uint16
Uint32
Uint16
Uint16
Uint8
Uint8
Uint16
Uint16
Uint16
Uint16
Uint8
Uint8
Uint8
Type
Uint8
Uint16
Uint16
Uint16
Uint16
Uint16
Uint16

Advertisement