Time Based Funtions - Danfoss VLT FC 103 Programming Manual

Refrigeration drive
Hide thumbs Also See for VLT FC 103:
Table of Contents

Advertisement

Parameter Lists
22-44
Wake-up Ref./FB Difference
22-45
Setpoint Boost
22-46
Maximum Boost Time
22-5* End of Curve
22-50
End of Curve Function
22-51
End of Curve Delay
22-6* Broken Belt Detection
22-60
Broken Belt Function
4
4
22-61
Broken Belt Torque
22-62
Broken Belt Delay
22-7* Short Cycle Protection
22-75
Short Cycle Protection
22-76
Interval between Starts
22-77
Minimum Run Time
22-78
Minimum Run Time Override
Minimum Run Time Override
22-79
Value
22-8* Flow Compensation
22-80
Flow Compensation
Square-linear Curve Approxi-
22-81
mation
22-82
Work Point Calculation
22-83
Speed at No-Flow [RPM]
22-84
Speed at No-Flow [Hz]
22-85
Speed at Design Point [RPM]
22-86
Speed at Design Point [Hz]
22-87
Pressure at No-Flow Speed
22-88
Pressure at Rated Speed
22-89
Flow at Design Point
22-90
Flow at Rated Speed
Table 4.19

4.1.19 23-** Time Based Funtions

Par. No. # Parameter description
23-0* Timed Actions
23-00
ON Time
23-01
ON Action
23-02
OFF Time
23-03
OFF Action
23-04
Occurrence
23-1* Maintenance
23-10
Maintenance Item
23-11
Maintenance Action
23-12
Maintenance Time Base
23-13
Maintenance Time Interval
23-14
Maintenance Date and Time
23-1* Maintenance Reset
23-15
Reset Maintenance Word
184
®
VLT
Refrigeration Drive Programming Guide
10 %
All set-ups
0 %
All set-ups
60 s
All set-ups
[0] Off
All set-ups
10 s
All set-ups
[0] Off
All set-ups
10 %
All set-ups
10 s
All set-ups
[0] Disabled
All set-ups
300 s
All set-ups
0 s
All set-ups
[0] Disabled
All set-ups
0 ProcessCtrlUnit
All set-ups
[0] Disabled
All set-ups
100 %
All set-ups
[0] Disabled
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
0 N/A
All set-ups
999999 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
Default value
4-set-up
ExpressionLimit
2 set-ups
[0] Disabled
2 set-ups
ExpressionLimit
2 set-ups
[0] Disabled
2 set-ups
[0] All days
2 set-ups
[1] Motor bearings
1 set-up
[1] Lubricate
1 set-up
[0] Disabled
1 set-up
1 h
1 set-up
ExpressionLimit
1 set-up
[0] Do not reset
All set-ups
®
MG16H102 - VLT
is a registered Danfoss trademark
TRUE
0
TRUE
0
TRUE
0
TRUE
-
TRUE
0
TRUE
-
TRUE
0
TRUE
0
TRUE
-
TRUE
0
TRUE
0
FALSE
-
TRUE
-3
TRUE
-
TRUE
0
TRUE
-
TRUE
67
TRUE
-1
TRUE
67
TRUE
-1
TRUE
-3
TRUE
-3
TRUE
-3
TRUE
-3
Change
Conver-
during
sion index
operation
TRUE
0
TRUE
-
TRUE
0
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
74
TRUE
0
TRUE
-
Int8
Int8
Uint16
Uint8
Uint16
Uint8
Uint8
Uint16
Uint8
Uint16
Uint16
Uint8
Int32
Uint8
Uint8
Uint8
Uint16
Uint16
Uint16
Uint16
Int32
Int32
Int32
Int32
Type
TimeOfDay-
WoDate
Uint8
TimeOfDay-
WoDate
Uint8
Uint8
Uint8
Uint8
Uint8
Uint32
TimeOfDay
Uint8