3.2.5 0-5* Copy/Save
Copy parameter settings between set-ups and to/from the
LCP.
0-50 LCP Copy
3
3
Option:
[0]
No copy
*
[1]
All to LCP
[2]
All from
LCP
[3]
Size indep.
from LCP
This parameter cannot be adjusted while the motor is
running.
0-51 Set-up Copy
Option:
[0]
No copy
*
[1]
Copy to set-
up 1
[2]
Copy to set-
up 2
[3]
Copy to set-
up 3
[4]
Copy to set-
up 4
[9]
Copy to all
3.2.6 0-6* Password
0-60 Main Menu Password
Range:
100
[-9999 -
*
9999 ]
34
VLT
Function:
No function
Copies all parameters in all set-ups from the
frequency converter memory to the LCP
memory. For service purposes it is
recommended to copy all parameters to the
LCP after commissioning.
Copies all parameters in all set-ups from the
LCP memory to the frequency converter
memory.
Copies only the parameters that are
independent of the motor size. The latter
selection can be used to programme several
frequency converters with the same function
without disturbing motor data which are
already set.
Function:
No function
Copies all parameters in the present
Programming Set-up (defined in
0-11 Programming Set-up) to Set-up 1.
Copies all parameters in the present
Programming Set-up (defined in
0-11 Programming Set-up) to Set-up 2.
Copies all parameters in the present
Programming Set-up (defined in
0-11 Programming Set-up) to Set-up 3.
Copies all parameters in the present
Programming Set-up (defined in
0-11 Programming Set-up) to Set-up 4.
Copies the parameters in the present set-up
over to each of the set-ups 1 to 4.
Function:
Define the password for access to the Main
Menu via the [Main Menu] key. If
0-61 Access to Main Menu w/o Password is
set to [0] Full access, this parameter will be
ignored.
MG16H102 - VLT
®
Refrigeration Drive Programming Guide
0-61 Access to Main Menu w/o Password
Option:
[0]
Full access
*
[1]
LCP: Read only Prevent unauthorized editing of Main Menu
[2]
LCP: No access Prevent unauthorized viewing and editing
[3]
Bus: Read only
[4]
Bus: No access
[5]
All: Read only
[6]
All: No access
If [0] Full access is selected then 0-60 Main Menu Password,
0-65 Personal Menu Password and 0-66 Access to Personal
Menu w/o Password will be ignored.
0-65 Personal Menu Password
Range:
200
[-9999 -
*
9999 ]
0-66 Access to Personal Menu w/o Password
Option:
[0]
Full access
*
[1]
LCP: Read only Prevents unauthorized editing of My
[2]
LCP: No access Prevents unauthorized viewing and editing
[3]
Bus: Read only
[4]
Bus: No access
[5]
All: Read only
[6]
All: No access
If 0-61 Access to Main Menu w/o Password is set to [0] Full
access, this parameter will be ignored.
3.2.7 0-7* Clock Settings
Set the time and date of the internal clock. The internal
clock can be used for e.g. Timed Actions, energy log, Trend
Analysis, date/time stamps on alarms, Logged data and
Preventive Maintenance.
It is possible to program the clock for Daylight Saving
Time/summertime, weekly working days/non-working days
including 20 exceptions (holidays etc.). Although the clock
settings can be set via the LCP, they can also be set along
with timed actions and preventative maintenance
functions using the MCT 10 software tool.
®
is a registered Danfoss trademark
Function:
Disables password defined in 0-60 Main
Menu Password.
parameters.
of Main Menu parameters.
Function:
Define the password for access to the My
Personal Menu via the [Quick Menu] key. If
0-66 Access to Personal Menu w/o Password
is set to [0] Full access, this parameter will
be ignored.
Function:
Disables password defined in 0-65 Personal
Menu Password.
Personal Menu parameters.
of My Personal Menu parameters.