Danfoss VLT FC 103 Programming Manual page 29

Refrigeration drive
Hide thumbs Also See for VLT FC 103:
Table of Contents

Advertisement

Parameter Description
0-12 This Set-up Linked to
Option:
3
3
[0]
Not linked
*
[1]
Set-up 1
[2]
Set-up 2
[3]
Set-up 3
[4]
Set-up 4
0-13 Readout: Linked Set-ups
Array [5]
Range:
0
[0 - 255 ] View a list of all the set-ups linked by means of
*
0-14 Readout: Prog. Set-ups / Channel
Range:
0
[-2147483648
*
- 2147483647 ]
28
VLT
Function:
OR
2. While still in Set-up 1, using 0-50 LCP Copy,
copy Set-up 1 to Set-up 2. Then set 0-12 This
Set-up Linked to to [2] Set-up 2. This will start
the linking process.
0 RPM
0.00A
Set-up Handling
0-12 This Set-up Linked to
[2]
Setup 2
Illustration 3.2
After the link is complete, 0-13 Readout: Linked
Set-ups will read {1,2} to indicate that all 'not
changeable during operation' parameters are
now the same in Set-up 1 and Set-up 2. If there
are changes to a 'not changeable during
operation' parameter, e.g. 1-30 Stator Resistance
(Rs), in Set-up 2, they will also be changed
automatically in Set-up 1. A switch between
Set-up 1 and Set-up 2 during operation is now
possible.
Function:
0-12 This Set-up Linked to. The parameter has one
index for each parameter set-up. The parameter
value displayed for each index represents which
set-ups are linked to that parameter set-up.
Index
LCP value
0
{0}
1
{1,2}
2
{1,2}
3
{3}
4
{4}
Table 3.2 Example: Set-up 1 and Set-up 2 are
linked
Function:
View the setting of 0-11 Programming Set-
up for each of the four different
MG16H102 - VLT
®
Refrigeration Drive Programming Guide
0-14 Readout: Prog. Set-ups / Channel
Range:
1(1)
0-1*
3.2.2 0-2* LCP Display
Define the variables displayed in the Graphical Local
Control Panel.
NOTE
Please refer to 0-37 Display Text 1, 0-38 Display Text 2 and
0-39 Display Text 3 for information on how to write display
texts.
0-20 Display Line 1.1 Small
Option:
[37]
Display Text 1
[38]
Display Text 2
[39]
Display Text 3
[89]
Date and Time
Readout
[953]
Profibus Warning
Word
[1005] Readout Transmit
Error Counter
[1006] Readout Receive
Error Counter
®
is a registered Danfoss trademark
Function:
communication channels. When the
number is displayed in hex, as it is in the
LCP, each number represents one channel.
Numbers 1-4 represent a set-up number; 'F'
means factory setting; and 'A' means active
set-up. The channels are, from right to left:
LCP, FC-bus, USB, HPFB1.5.
Example: The number AAAAAA21h means
that the FC-bus selected Set-up 2 in
0-11 Programming Set-up, the LCP selected
Set-up 1 and all others used the active set-
up.
Function:
Select a variable for display in line
1, left position. Default setting is
application dependent.
Enables an individual text string to
be written, for display in the LCP or
to be read via serial communi-
cation.
Enables an individual text string to
be written, for display in the LCP or
to be read via serial communi-
cation.
Enables an individual text string to
be written, for display in the LCP or
to be read via serial communi-
cation.
Displays the current date and time.
Displays Profibus communication
warnings.
View the number of CAN control
transmission errors since the last
power-up.
View the number of CAN control
receipt errors since the last power-
up.