Danfoss VLT FC 103 Programming Manual page 50

Refrigeration drive
Hide thumbs Also See for VLT FC 103:
Table of Contents

Advertisement

Parameter Description
2-16 AC brake Max. Current
Range:
Function:
100 %
[
0 - 1000.0
Enter the maximum permissible current
*
%]
when using AC brake to avoid
overheating of motor windings. The AC
brake function is available in Flux mode
only.
NOTE
2-16 AC brake Max. Current will not have effect when
1-10 Motor Construction = [1] PM, non salient SPM.
2-17 Over-voltage Control
Option:
[0]
Disabled
No OVC required.
[2]
Enabled
Activates OVC.
*
NOTE
2-17 Over-voltage Control will not have effect when
1-10 Motor Construction = [1] PM, non salient SPM.
NOTE
The ramp time is automatically adjusted to avoid tripping
of the frequency converter.
®
VLT
Refrigeration Drive Programming Guide
Function:
®
MG16H102 - VLT
is a registered Danfoss trademark
3