Air Conditioning - Goldacres Crop Cruiser G6 Operator's Manual

Table of Contents

Advertisement

Air Conditioning

PROBLEM
Air conditioning not cooling
effectively.
156 - Chapter 11 - Troubleshooting
COMMON CAUSES
Condenser Blocked
Compressor belt loose.
A/C system needs re-gassing
Evaporator blocked
G4.7, G5, G6 Crop Cruiser Operator's Manual MY19 - REV 0
COMMON SOLUTION
Check the condenser for a build up of dirt
and plant matter, clean if required.
Inspect the belt to see if it is tensioned
correctly. If belt is showing signs of wear,
replace.
If this is the case, only allow a qualified air
conditioning technician to work on the
system. R134a refrigerant must not be
allowed to escape to the atmosphere.
Build up of dirt and plant matter, clean if
required. Be careful not to damage any of
the components.