Hydraulic Fill Pump - Goldacres Crop Cruiser G6 Operator's Manual

Table of Contents

Advertisement

Hydraulic Fill Pump

Suction & Delivery Lines
• Use good quality suction hose and fittings that will
not collapse or leak air under suction
• If pumping water from structures other than
storage tanks, we recommend the use of an
appropriate sized floating filter equipped with a
check valve
• It is essential the suction line to the pump is the
same size as the suction port (3") to achieve
maximum pump output
A smaller size delivery line can be used but will
reduce pump output.
3" Fill Pump - Operation
1. Connect the 3" fill hose (not supplied) to quick fill
cam lock coupling under the EZ Control POD.
2. Turn the 'Main Tank Fill' ball valve ON
NOTE: Do not turn the tank fill ball valve off
while the pump is running.
3. With the engine running at low idle, turn the 'Fill
Pump' switch ON.
NOTE: Do not turn the fill pump switch ON or
OFF with the engine above low idle.
166 - Chapter 12 - Optional Accessories
4. Once the pump is running, turn the 'RPM Raise'
switch ON.
5. When the tank has been filled to the desired
level, turn the 'RPM Raise' switch to OFF.
6. When the engine has returned to low idle, turn
the 'Fill Pump' switch OFF. Close the 'Main Tank Fill'
ball valve and remove the water supply from the
tank fill fitting.
Setting Hydraulic Fill Pump RPM
The 3" fill pump speed can be altered by adjusting
the screw and lock on the rear of the hydraulic
motor. The hydraulic system has been sized so that
the fill pump can not be over revved, so the speed
control should be wound all the way out.