Chemical Transfer Flow Meter
The MODE button performs the following functions:
1. If the display is off, press MODE button to display
current total (CUR).
2. Use MODE button to cycle between CURRENT
TOTAL (CUR) and CUMULATIVE TOTAL (CUM).
NOTE: After approximately 30 seconds, display will
automatically switch from CUMULATIVE TOTAL
(CUM) back to CURRENT TOTAL (CUR).
3. Press and hold MODE button for 3–5 seconds to
show Volume Unit Selection. Press INCREASE or
DECREASE buttons to cycle through volume units.
When desired units are flashing, press MODE
button to save selection and return to CURRENT
TOTAL (CUR).
Volume Unit Selection choices are: GALLONS
(GAL), LITERS (LTR), or COUNTS (CNT).
NOTE: To reset CURRENT TOTAL (CUR) to Zero,
press and hold DECREASE button for 2 seconds or
more while CURRENT TOTAL (CUR) is displayed.
NOTE: Meter will not enter Volume Unit Selection
mode if pump is running.
NOTE: CUMULATIVE TOTAL CANNOT BE RESET
- EVEN BY REMOVING THE BATTERY.
The flow meter display will turn on whenever
flow is detected.
The flow meter and display will turn off after a
3-minute period of button or flow inactivity. Any
unsaved changes will not be saved.
Calibration
Calibration procedures are the same for both
the 90° and in-line meters.
To ensure accuracy, purge all air from pump/
meter system before calibrating.
TO CALIBRATE (CAL) METER:
1. Press MODE button to turn meter on.
2. Press and hold MODE button for 3–5 seconds to
show Volume Unit Selection. Press INCREASE or
DECREASE buttons to select desired Volume
Units.
162 - Chapter 12 - Optional Accessories
3. Press and hold MODE button again for 3–5
seconds to enter Calibration Mode (CAL).
4. CAL and chosen Volume Unit (GAL or LTR) will
blink together. Numeric Display will show default
values as listed below.
FLASHING
INDICATORS
Calibrate Litres (LTR)
Calibrate Gallons (GAL)
Calibrate Counts (CNT)
NOTE: XXXX represents the present COUNTS
(CNT) value stored in flow meter's memory. To
Calibrate using COUNTS (CNT), see next section.
NOTE: To use a calibrated container with a volume
other than the default values, press INCREASE or
DECREASE buttons to change value shown on
Numeric Display.
5. To complete CALIBRATION for GALLONS
(GAL) or LITERS (LTR), pump the exact amount
shown on Numeric Display.
6. Press MODE button for 3–5 seconds to SAVE the
CALIBRATION. Display will show CAL if
CALIBRATION was successful.
NOTE: If MODE button is pressed for less than 3
seconds, CALIBRATION will be aborted and display
will show Err (Error) to indicate the CALIBRATION
was not successful. Display will return to CURRENT
TOTAL (CUR) without making any changes.
TO CALIBRATE (CAL) METER USING COUNTS
(CNT) VALUE:
NOTE: No pumping is required to complete
CALIBRATION (CAL) for COUNTS (CNT).
1. Press MODE button to turn meter on.
2. Press and hold MODE button for 3–5 seconds to
show Volume Unit Selection. Press INCREASE or
DECREASE buttons to select COUNTS (CNT).
3. Press and hold MODE button again for 3–5
seconds to enter Calibration Mode (CAL).
G4.7, G5, G6 Crop Cruiser Operator's Manual MY19 - REV 0
NUMERIC DISPLAY
20.00
5.00
XXXX
Continued over page