Goldacres Crop Cruiser G6 Operator's Manual page 41

Table of Contents

Advertisement

CANtrak System
Distance Remaining: If the data required for Fuel
Remaining and Average Distance Per Volume is
available, it is calculated using: Average Distance Per
Volume x Fuel Remaining
NOTE: Reset - which affects all resettable fuel
computer parameters - is performed by allowing the
button bar to disappear and pressing and holding key
1 for at least 3 seconds. If the button bar is visible
then the display will move to the next parameter
before the Reset. Setting Fuel Tank Reset and Total
Fuel Tank Data is performed via the Configuration
menu.
The Quad Display - Key 2
Quad display mode provides 4 gauges. To select it,
press any of the keys 1 to 4 to show the top-level
button bar and then key 2. Repeat presses of key 2
cycle the display around 3 separate quad screens:
as a default these screens show 4 digital gauges
(RPM, temperature, battery voltage, oil pressure), 4
analogue gauges (same as digital), and 4 alternative
analogue gauges. All 12 gauges may be selected and
configured by users, providing a simple means of
creating application-specific views of engine data.
Gauges are selected via quad display's 'adjust mode',
by pressing key 5 (noted by an arrow icon) when
GEM is running quad display and the button bar is
visible. In adjust mode, corresponding key presses
cycle the display through available parameters. The
selected configuration is stored even when power is
removed; adjust mode is exited by pressing key 5.
G4.7, G5, G6 Crop Cruiser Operator's Manual MY19 - REV 0
Above: Three default display setups available in quad-
display mode.
Above: Adjust mode; allows users to select the
individual gauge types displayed.
The Uni Display - Key 3
GEM's Uni display mode plots data history in one
large window - in an X-Y graph format similar to a
pen plotter. This mode is selected by pressing any
of the first 4 keys to show the top-level button
bar and then key 3. Data is shown in graph form,
with the most recent data scrolling from right to
left. The viewed time range may be adjusted in the
Configuration menu from 2 minutes to 8 hours in
six steps. Maximum and minimum values of the Y
axis (the reading span) are adjusted automatically
to give an optimum view of data. The parameter
displayed is selectable by repeatedly pressing key 3
while in the graph display mode. The parameters that
may be displayed are listed in the next section.
Above: Example graph display plotting battery
voltage.
Chapter 4 - Cabin - 37

Advertisement

Table of Contents
loading

Table of Contents