Goldacres Crop Cruiser G6 Operator's Manual page 30

Table of Contents

Advertisement

Lighting
Egress Lighting
These machines are fitted with egress lighting to
assist with safely exiting the machine when parking in
dark conditions. There is a timed relay that will keep
the outside work lights on for 30 seconds after the
machine has been shut down and the key removed.
The amount of time that the relay keeps the lights
on for can be adjusted. It is found inside the main
cabin fuse box area.
Above: Egress lighting timer relay location in main
fuse box area.
A
B
Above: Timer relay potentiometer and dip switches.
By default, the timer potentiometer is set to 30
seconds (A). It has a range between 0 and 60
seconds. Turning it clockwise increases the timer.
Turning it anti-clockwise decreases the timer.
The two dimples in the white adjuster indicate the
direction it is pointing in.
The two dip switches are set to the OFF position by
default (B). If a lighting time longer than 60 seconds
(1 minute) is required, then dip switch 2 can be set
to the ON position. On this setting, each increment
on the potentiometer represents 1 minute, for a
maximum of range of 1 to 60 minutes.
26 - Chapter 4 - Cabin
G4.7, G5, G6 Crop Cruiser Operator's Manual MY19 - REV 0

Advertisement

Table of Contents
loading

Table of Contents