Chemical Transfer Flow Meter
The FM-1100 Flow Meter is a positive displacement
fluid metering unit.
• Accuracy: +/-0.5%
• Flow Range: 9-136 L/min
• Maximum Pressure: 410 kPa (60 PSI)
Operation
CAUTION: Exposure to chemical can cause serious
injuries, always wear proper protective clothing and
devices when transferring chemical. Refer to and
follow chemical manufacturers instructions.
The FM-1100 flow meter will start working
automatically when flow is detected.
The LCD display will show the following:
- LOW - Low battery indicator
- CUR - Current Total indicator
- CUM - Cumulative total indicator
- GAL - Gallons indicator
- LTR - Litre indicator
- CNT - counts indicator
- CAL - Calibration indicator
The meter displays and stores:
• A resettable CURRENT TOTAL (CUR)
• A non-resettable CUMULATIVE TOTAL (CUM)
• A COUNTS calibration value (CNT)
G4.7, G5, G6 Crop Cruiser Operator's Manual MY19 - REV 0
• Maximum Total: 9999
• Auto Shut Off: 3 minute
• Auto Wake Up: With Flow
Meter Operation
The FM-1100 Series Flow Meter has three push buttons:
1 MODE or
2 INCREASE
"ON" button
(up arrow) button
MODE/
INCREASE
ON
The meter displays and stores:
• A resettable CURRENT TOTAL (CUR)
• A non-resettable CUMULATIVE TOTAL (CUM)
• A COUNTS calibration value (CNT)
The MODE button performs the following functions:
1. If the display is off, press MODE button to display
current total (CUR).
Chapter 12 - Optional Accessories - 161
2. Use MODE button to cycle between CURRENT
TOTAL (CUR) and CUMULATIVE TOTAL (CUM).
NOTE: After approximately 30 seconds, display will auto-
matically switch from CUMULATIVE TOTAL (CUM) back
to CURRENT TOTAL (CUR).
• The flow meter display
detected.
• The flow meter will turn
a 3-minute period of bu
unsaved changes will n
Calibration Procedu
• Calibration procedures
and inline meters.
• To ensure accuracy, pu
system before calibrati
To CALIBRATE (CAL) m
1. Press MODE button to
2. Press and hold MODE
show Volume Unit Se
3 DECREASE
DECREASE buttons t
(down arrow) or
3. Press and hold MODE
"ZERO" button
to enter Calibration M
4. CAL and chosen Volu
together. Numeric Dis
listed below.
DECREASE/
ZERO
NOTE: To use a calibrate
than the default values, p
buttons to change value
5. To complete CALIBRA
LITERS (LTR), pump
Numeric Display.
6. Press MODE button fo
CALIBRATION. Displa
TION was successful.