Flow Meter & Controller - Goldacres Crop Cruiser G6 Operator's Manual

Table of Contents

Advertisement

Flow Meter & Controller
PROBLEM
Application rate is
inaccurate, unstable
or zero
Speed sensor display
is inaccurate, unstable
or zero
Volume display is
inaccurate, unstable,
zero or not changing
Flow meter appears
not to be working
Application rate or
pressure will not alter
Control valve has
failed
Raven Console not
working
If the flow meter fails to give accurate readings, the following actions should be taken:
• Adjust the spraying pressure by putting the flow control switch into manual and using the increase decrease
switch to adjust to the desired pressure as shown on the pressure gauge on the sprayer.
• Drive the sprayer at a constant speed in order to apply the required application volume as determined by
the nozzle selection chart.
• The sprayer should then be operated to empty the tank. Once the sprayer is empty of chemical, partially fill
the tank with fresh water so that test can be performed in order to correct the problem. Repair or replace
the flow meter as soon as possible.
G4.7, G5, G6 Crop Cruiser Operator's Manual MY19 - REV 0
COMMON CAUSES
Incorrect console calibration
Inconsistent ground speed
reading
Inconsistent flow meter
reading
Faulty control valve
Incorrect speed calibration
Faulty cable
Meter calibration is incorrect Reset meter calibration
Flow meter cable pins are
corroded
Flow meter is pointing the
wrong way
Faulty cable
Flow meter is seized or
blocked
Faulty cable
Calibration figure is incorrect Reset meter calibration
Faulty control valve
Faulty cable
Faulty valve
No power supply
COMMON SOLUTION
Re-calibrate console
Check cabling
Replace flow meter
Replace control valve
Check using manual increase/decrease flow control
Re-calibrate console speed
Test cable as per instructions following
Replace flow meter plugs & pins
Disconnect flow meter and reinstall in the correct
orientation
Manually test the cable
Remove and clean any foreign materials so the
turbine spins freely
Test cable as per instructions following
Test valve manually and replace if required
Replace control valve
Temporary solutions:
Remove the motor from the 3 way ball valve and
manually adjust the flow by turning the shaft with a
spanner
Check loom connection at the back of the console
Check connection to battery terminals
Check the fuse in the back of the console
With a multi meter, check the voltage potential across
pins 1(-) and 16(+) on the 16 pin plug going into the
console (Should be at least 12v)
Chapter 11 - Troubleshooting - 151

Advertisement

Table of Contents
loading

Table of Contents