[Pr. PF43_Friction failure prediction - Standard deviation (PSD)]
Initial value
0 [0.1 %]
Set the friction torque standard deviation at the rated speed.
This servo parameter is enabled when [Pr. PF34.0 Friction failure prediction warning selection] is set to "2" (Enabled (Manual
threshold setting)).
When [Pr. PF34.0 Friction failure prediction warning selection] is set to "1" (Enabled (Automatic threshold setting)), the value
will be calculated automatically from the estimated friction torque at rated speed.
[Pr. PF45_Vibration failure prediction - Average characteristic
(VAV)]
Initial value
0 [0.1 %]
Set a vibration level average during servo motor operation.
This servo parameter is enabled when [Pr. PF34.0 Friction failure prediction warning selection] is set to "2" (Enabled (Manual
threshold setting)).
When [Pr. PF34.0 Friction failure prediction warning selection] is set to "1" (Enabled (Automatic threshold setting)), the value
will be calculated automatically from the estimated friction torque at rated speed.
Setting range
0 to 20000
Setting range
0 to 10000
Setting method
Each axis
Setting method
Each axis
1 DETAILED LISTS OF SERVO PARAMETERS
1.7 Extension setting 3 servo parameters group ([Pr. PF_ _ ])
Supported software version
A0
Supported software version
A0