[Pr. PB47.2_Notch width selection]
Initial value
0h
0: α = 2
1: α = 3
2: α = 4
3: α = 5

[Pr. PB48_Machine resonance suppression filter 4 (NH4)]

Initial value
4500 [Hz]
Set the notch frequency of the machine resonance suppression filter 4.
When [Pr. PB49.0 Machine resonance suppression filter 4 selection] is set to "1" (Enabled), set the notch frequency with this
servo parameter.

[Pr. PB49_Notch shape selection 4 (NHQ4)]

Initial value
00000000h
Set forms of the machine resonance suppression filter 4.
[Pr. PB49.0_Machine resonance suppression filter 4 selection]
Initial value
0h
0: Disabled
1: Enabled
When this setting value is "Enabled", [Pr. PB17 Shaft resonance suppression filter] cannot be used.
[Pr. PB49.1_Notch depth selection]
Initial value
0h
0: -40 dB
1: -14 dB
2: -8 dB
3: -4 dB
[Pr. PB49.2_Notch width selection]
Initial value
0h
0: α = 2
1: α = 3
2: α = 4
3: α = 5
Setting range
0h to 3h
Setting range
10 to 9000
Setting range
00000000h to 00000331h
Setting range
0h to 1h
Setting range
0h to 3h
Setting range
0h to 3h
Supported software version
A0
Setting method
Each axis
Setting method
Each axis
Supported software version
A0
Supported software version
A0
Supported software version
A0
1 DETAILED LISTS OF SERVO PARAMETERS
1.3 Gain/filter setting servo parameters group ([Pr. PB_ _ ])
Supported software version
A0
Supported software version
Refer to each detail No.