[Pr. PB23_Low-pass filter selection (VFBF)]

Initial value
00001000h
[Pr. PB23.0_Shaft resonance suppression filter selection]
Initial value
0h
Select the shaft resonance suppression filter.
0: Automatic setting
1: Manual setting
2: Disabled
When [Pr. PB49.0 Machine resonance suppression filter 4 selection] is set to "1" (Enabled), the shaft resonance suppression
filter cannot be used.
[Pr. PB23.1_Low-pass filter selection]
Initial value
0h
Select the low-pass filter.
0: Automatic setting
1: Manual setting
2: Disabled
When "5" (Quick tuning mode) is selected in [Pr. PA08.0 Gain adjustment mode selection], this servo parameter is set to "2"
(Manual setting).
[Pr. PB23.3_Shaft resonance suppression filter 2 selection]
Initial value
1h
0: Disabled
1: Automatic setting
1 DETAILED LISTS OF SERVO PARAMETERS
36
1.3 Gain/filter setting servo parameters group ([Pr. PB_ _ ])
Setting range
00000000h to 00001022h
Setting range
0h to 2h
Setting range
0h to 2h
Setting range
0h to 1h
Setting method
Each axis
Supported software version
A0
Supported software version
A0
Supported software version
A0
Supported software version
Refer to each detail No.