[Pr. Pb19_Vibration Suppression Control 1 - Vibration Frequency (Vrf11)]; [Pr. Pb20_Vibration Suppression Control 1 - Resonance Frequency (Vrf12)]; [Pr. Pb21_Vibration Suppression Control 1 - Vibration Frequency Damping (Vrf13)]; [Pr. Pb22_Vibration Suppression Control 1 - Resonance Frequency Damping (Vrf14)] - Mitsubishi Electric MELSERVO-J5 MR-J5-G Series User Manual

Ac servo system
Hide thumbs Also See for MELSERVO-J5 MR-J5-G Series:
Table of Contents

Advertisement

[Pr. PB19_Vibration suppression control 1 - Vibration frequency
(VRF11)]
Initial value
100.0 [Hz]
Set the vibration frequency of vibration suppression control 1 to suppress low-frequency machine vibration.
When "1" (Automatic setting) is selected in [Pr. PB02.0 Vibration suppression control 1 - Tuning mode selection], this servo
parameter will be set automatically. When "2" (Manual setting) is selected, set the vibration frequency with this servo
parameter.
When [Pr. PB25.0 Model adaptive control selection] is set to "2" (Disabled), the vibration suppression control cannot be used.
The usable range of [Pr. PB19 Vibration suppression control 1 - Vibration frequency] depends on the value in [Pr. PB07 Model
control gain]. If the setting value of [Pr. PB19 Vibration suppression control 1 - Vibration frequency] is out of the range, the
vibration suppression control is disabled.
[Pr. PB20_Vibration suppression control 1 - Resonance
frequency (VRF12)]
Initial value
100.0 [Hz]
Set the resonance frequency for vibration suppression control 1 to suppress low-frequency machine vibration.
When "1" (Automatic setting) is selected in [Pr. PB02.0 Vibration suppression control 1 - Tuning mode selection], this servo
parameter will be set automatically. When "2" (Manual setting) is selected, set the resonance frequency with this servo
parameter.
When [Pr. PB25 Model adaptive control selection] is set to "2" (Disabled), the vibration suppression control cannot be used.
The usable range of [Pr. PB20 Vibration suppression control 1 - Resonance frequency] changes depending on the value in
[Pr. PB07 Model control gain]. If the setting value of [Pr. PB20 Vibration suppression control 1 - Resonance frequency] is out
of the range, the vibration suppression control is disabled.
[Pr. PB21_Vibration suppression control 1 - Vibration frequency
damping (VRF13)]
Initial value
0.00
Set the damping of the vibration frequency for vibration suppression control 1 to suppress low-frequency machine vibration.
When "1" (Automatic setting) is selected in [Pr. PB02.0 Vibration suppression control 1 - Tuning mode selection], this servo
parameter will be set automatically. When "2" (Manual setting) is selected, set the damping of the vibration frequency with this
servo parameter.
[Pr. PB22_Vibration suppression control 1 - Resonance
frequency damping (VRF14)]
Initial value
0.00
Set a damping of the resonance frequency for vibration suppression control 1 to suppress low-frequency machine vibration.
When "1" (Automatic setting) is selected in [Pr. PB02.0 Vibration suppression control 1 - Tuning mode selection], this servo
parameter will be set automatically. When "2" (Manual setting) is selected, set the damping of the resonance frequency with
this servo parameter.
Setting range
0.1 to 300.0
Setting range
0.1 to 300.0
Setting range
0.00 to 0.30
Setting range
0.00 to 0.30
Setting method
Each axis
Setting method
Each axis
Setting method
Each axis
Setting method
Each axis
1 DETAILED LISTS OF SERVO PARAMETERS
1.3 Gain/filter setting servo parameters group ([Pr. PB_ _ ])
Supported software version
A0
Supported software version
A0
Supported software version
A0
Supported software version
A0
1
35

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melservo-j5 mr-j5w-g series

Table of Contents