[Pr. Pf80_Drive Recorder - Operation Condition Selection (Drmc)] - Mitsubishi Electric MELSERVO-J5 MR-J5-G Series User Manual

Ac servo system
Hide thumbs Also See for MELSERVO-J5 MR-J5-G Series:
Table of Contents

Advertisement

[Pr. PF80_Drive recorder - Operation condition selection (DRMC)]

Initial value
00000000h
[Pr. PF80.0_Drive recorder - Operation mode selection]
Initial value
0h
0: Automatic setting mode
1: Manual setting mode
When "0" (Automatic setting mode) is set, the setting values of [Pr. PF81 Drive recorder - Sampling operation selection] to [Pr.
PF94 Drive recorder - Digital channel setting 4] are disabled. The drive recorder will be activated automatically at the same
time as an alarm occurs.
When obtaining desired analog data from the drive recorder, set this servo parameter to "1" (Manual setting mode) to set the
trigger conditions and sampling cycle, and then start sampling with [Pr. PF81.0 Drive recorder - Sampling start selection].
To disable the drive recorder, set [Pr. PF21 Drive recorder switching time setting] to "-1" (Drive recorder function disabled).
[Pr. PF80.2-3_Drive recorder - Sampling cycle selection]
Initial value
00h
Set the sampling cycle of the drive recorder.
When [Pr. PF80.0] is set to "0" (Automatic setting mode), the setting value of this servo parameter is disabled.
Setting value
00
05
06
07
08
09
0A
0B
0C
0D
0E
0F
10
11
1 DETAILED LISTS OF SERVO PARAMETERS
88
1.7 Extension setting 3 servo parameters group ([Pr. PF_ _ ])
Setting range
00000000h to 00001F01h
Setting range
0h to 1h
Setting range
00h to 1Fh
Setting method
Each axis
Supported software version
A0
Supported software version
A0
8 kHz class
Automatic (250 μs)
250 μs
500 μs
1 ms
2 ms
4 ms
8 ms
16 ms
32 ms
64 ms
128 ms
256 ms
512 ms
1.024 s
Supported software version
Refer to each detail No.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melservo-j5 mr-j5w-g series

Table of Contents