[Pr. PB17_Shaft resonance suppression filter (NHF)]

Initial value
00000000h
Set the shaft resonance suppression filter.
Use this to suppress a high-frequency machine vibration.
When [Pr. PB23.0 Shaft resonance suppression filter selection] is set to "0" (Automatic setting), the value will be calculated
automatically from the servo motor used and load to motor inertia ratio. This servo parameter is not automatically set when
the linear servo motor is used. When "1" (Manual setting) is selected, set the shaft resonance suppression filter with this servo
parameter.
When [Pr. PB23.0 Shaft resonance suppression filter selection] is set to "2" (Disabled), the setting value is disabled.
When [Pr. PB49.0 Machine resonance suppression filter 4 selection] is set to "1" (Enabled), the shaft resonance suppression
filter cannot be used.
When [Pr. PB23.0 Shaft resonance suppression filter selection] is set to "2" (Disabled), the performance may be reduced.
[Pr. PB17.0-1_Shaft resonance suppression filter setting - Frequency selection]
Initial value
00h
Refer to the following table for setting values.
Set the value closest to the required frequency.
Setting value
00
01
02
03
04
05
06
07
08
09
0A
0B
0C
0D
0E
0F
10
11
12
13
14
15
16
17
18
19
1A
1B
1C
1D
1E
Setting range
00000000h to 0000039Fh
Setting range
00h to 9Fh
Setting method
Each axis
Supported software version
A0
Frequency [Hz]
Disabled
Disabled
4500
3000
2250
1800
1500
1285
1125
1000
900
818
750
692
642
600
562
529
500
473
450
428
409
391
375
360
346
333
321
310
300
1 DETAILED LISTS OF SERVO PARAMETERS
1.3 Gain/filter setting servo parameters group ([Pr. PB_ _ ])
Supported software version
Refer to each detail No.