1.5
I/O setting servo parameters group ([Pr. PD_ _ ])
[Pr. PD01_Input signal automatic on selection 1 (*DIA1)]
Initial value
00000000h
[Pr. PD01.0_For manufacturer setting]
This servo parameter is for manufacturer setting.
[Pr. PD01.1_For manufacturer setting]
This servo parameter is for manufacturer setting.
[Pr. PD01.2_Input signal automatic ON selection]
Initial value
0h
Select input devices that turn on automatically.
Setting digit (BIN)
_ _ _ x
_ _ x _
_ x _ _
x _ _ _
[Pr. PD01.3_For manufacturer setting]
This servo parameter is for manufacturer setting.
[Pr. PD01.4_For manufacturer setting]
This servo parameter is for manufacturer setting.
[Pr. PD01.5_For manufacturer setting]
This servo parameter is for manufacturer setting.
[Pr. PD01.6_For manufacturer setting]
This servo parameter is for manufacturer setting.
[Pr. PD01.7_For manufacturer setting]
This servo parameter is for manufacturer setting.
1 DETAILED LISTS OF SERVO PARAMETERS
66
1.5 I/O setting servo parameters group ([Pr. PD_ _ ])
Setting range
00000000h to 00000FF0h
Setting range
Setting method
Each axis
Supported software version
A0
Function
Forward rotation stroke end (LSP)
0: Use for an external input signal.
1: Automatic on
Reverse rotation stroke end (LSN)
0: Use for an external input signal.
1: Automatic on
Supported software version
Refer to each detail No.