[Pr. Pc17_Function Selection C-4 (**Cop4)]; [Pr. Pc19_Function Selection C-6 (*Cop6)] - Mitsubishi Electric MELSERVO-J5 MR-J5-G Series User Manual

Ac servo system
Hide thumbs Also See for MELSERVO-J5 MR-J5-G Series:
Table of Contents

Advertisement

[Pr. PC16.5_Servo motor incorrect wiring detection function execution method
selection]
Initial value
0h
Set the execution method for the servo motor incorrect wiring detection function.
0: Detect servo motor incorrect wiring at initial servo-on after enabling servo motor incorrect wiring detection
1: Detect servo motor incorrect wiring at initial servo-on after cycling the power
When [Pr. PC16.4] is set to "0" (disabled), the servo motor incorrect wiring detection function is not executed regardless of the
setting value in this servo parameter.
When this servo parameter is set to "0" (disabled), servo motor incorrect wiring detection is executed at initial servo-on, and
then after the detection is completed, [Pr. PC16.4] will be set to "0" (disabled).

[Pr. PC17_Function selection C-4 (**COP4)]

Initial value
00000000h
[Pr. PC17.1_Linear encoder multipoint Z-phase input - Function selection]
Initial value
0h
When multiple reference marks exist during the full stroke of the linear encoder, set "1".
0: Disabled
1: Enabled

[Pr. PC19_Function selection C-6 (*COP6)]

Initial value
00000000h
[Pr. PC19.0_[AL. 099 Stroke limit warning] selection]
Initial value
0h
Enable or disable [AL. 099 Stroke limit warning].
When "Disabled" is selected, [AL. 099] does not occur while LSP (Forward rotation stroke end) or LSN (Reverse rotation
stroke end) is off, but the operation will be stopped with the stroke limit.
0: Enabled
1: Disabled
[Pr. PC19.4_Output open phase detection selection]
Initial value
0h
Enable or disable the detection of output open phase.
0: Disabled
1: Enabled
Setting range
0h to 2h
Setting range
00000000h to 00000010h
Setting range
0h to 1h
Setting range
00000000h to 00111111h
Setting range
0h to 1h
Setting range
0h to 1h
Supported software version
A0
Setting method
Each axis
Supported software version
A0
Setting method
Each axis
Supported software version
A0
Supported software version
A0
1 DETAILED LISTS OF SERVO PARAMETERS
1.4 Extension setting servo parameters group ([Pr. PC_ _ ])
Supported software version
Refer to each detail No.
Supported software version
Refer to each detail No.
1
59

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melservo-j5 mr-j5w-g series

Table of Contents