ADJUSTMENTS
Connect the PRESSURE
GAUGE here
6
.
Key in 3585 to bring all motors to HOME POSITION.

PNEUMATIC SYSTEM FILM POCKET

A. VACUUM PUMP FOR FILM POCKET
PURPOSE:
The vacuum has to be in the correct range. If the vacuum is too low a FILM might not be
picked up in the MAGAZINE. If the vacuum is too high more than one FILM might be picked
up from the MAGAZINE.
1
.
Connect VACUUM GAUGE.
Connect the
VACUUM GAUGE
here
KODAK AG, Stuttgart
figure 4-87
VACUUM
SWITCH
FINE ADJUST-
MENT SCREW
figure 4-88
4-85
3053-3
VACUUM PUMP
MAGAZINE
BRASS NUT
LOCK NUT
12/1998