3053-3
TUNNEL SENSOR TSF / TSR (ML700 only)
REPAIR KIT 9194426
PURPOSE:
The original TUNNEL SENSOR 9188606 is no longer available. It is replaced with REPAIR
KIT 9194426.
1
.
Connect the DVM to the RECEIVER TEST POINTS (red and black).
R E C E I V E R
T S F / T S R
T R A N S M I T T E R
T S F / T S R
2
.
Change the position of the RECEIVER PCB until the voltage is below 500 mV.
3
.
Interrupt the light path with a fresh FILM. The voltage must now be higher
than 1.5 V. It might be necessary to change the position of the TRANSMITTER PCB if
the correct voltage cannot be reached.
12/1998
T e s t p o i n t r e d
F I L M P A T H
figure 4-84
T e s t p o i n t b l a c k
4-82
ADJUSTMENTS
KODAK AG, Stuttgart