Film Out Of Cassette Sensor Foc Repair Kit 9194416 (Intermediate Version) - Kodak MULTILOADER 700 Service Manual

Hide thumbs Also See for MULTILOADER 700:
Table of Contents

Advertisement

SM 3053-3
FILM OUT OF CASSETTE SENSOR FOC
REPAIR KIT 9194416 (Intermediate version)
Note
This REPAIR KIT is for the ML700 only!
The FILM OUT OF CASSETTE SENSOR FOC PN 9181106 is no longer available. It is
replaced with this REPAIR KIT. This kit cannot be used in a ML700 Plus.
The new RECEIVER PCB has 2 TEST POINTS (red and black) to ease the adjustment. To
get access to them the RECEIVER PCB has to be installed underneath the cassette level
and the TRANSMITTER PCB at the long MOUNTING BRACKET above it.
1
.
Switch off the ML700.
2
.
Open the TOP COVER, the right-hand SIDE PANEL and take off the REAR PANEL.
3
.
Take out the defective SENSOR. (always replace RECEIVER and TRANSMITTER).
4
.
Disconnect the SENSOR from PCB A9 CONNECTORS A9X2 and A9X2A.
Note
It might be possible that the distance between the 2 holes for mounting the FOC
TRANSMITTER PCB are too close together. Enlarge the holes in the MOUNTING BRACKET
as required. Be sure that the opening / closing of the EXIT DOOR does not interfere
with the SENSOR.
5
Mount the new SENSOR PCBs. See the drawing on the next page.
6
.
Connect the FOC TRANSMITTER to CONNECTOR A9X2 and the FOC RECEIVER
PCB to CONNECTOR A9X2A.
7
.
Switch on the ML700.
8
.
Connect the DVM to the RECEIVER TEST POINTS (red and black).
9
.
Change the position of the TRANSMITTER PCB until the voltage is below 500 mV.
As the light distribution of the TRANSMITTER is not even across the illuminated area, it
might be necessary to tilt the TRANSMITTER PCB sideways a small amount. If it is still
not possible to achieve a voltage < 500 mV, then record the lowest possible voltage
and proceed with step 10, or else proceed with step 13.
10.
Connect the DVM with the GROUND LEAD to TP 2 of PCB A9. Connect the
positive lead to the upper wire of RESISTOR R9 PCB A9.
See the drawing on page 3-10..
11.
Adjust R27 until the voltage is the minimum value reached in step 9 + 400 mV.
12/1998
3-8
REPAIR KITS
KODAK AG, Stuttgart