REPLACEMENT MAGAZINE OPENER MOTOR M6

1
.
Power down ML 700.
2
.
Unplug ML 700.
3
.
Take off REAR PANEL.
4
.
Open LEFT SIDE PANEL.
5
.
Unplug MOTOR M6.
6
.
Remove SCREW 1, take out CONNECTING LINK and discard it.
CONNECTING LINK
SCREW 1
MOUNTING BRACKET
MOTOR MOUNTING
SCREW
HEX SCREW
7
.
Remove SENSORS B20/21.
8
.
Mark position of MOUNTING BRACKET.
9
.
Remove 2 HEX SCREWS.
10
. Take out MOUNTING BRACKET with MOTOR M6.
11
. Remove 4 MOTOR MOUNTING SCREWS.
12
. Install new MOTOR. Use the CONNECTING LINK deliverred with the new motor.
The old CONNECTING LINK may cause a short circuit on PCB A10. Check that
MOTOR M6 does not touch PCB A10.
13
. Adjust MAGAZINE OPENER MOTOR M6
12/1998