ADJUSTMENTS
DOUBLE FILM SENSOR B14 (DFS)
ML700 UP TO SN 1022
1
.
Connect negative lead of DVM to TP1 on PCB A7.
2
.
Connect positive lead of DVM to TP3 on PCB A7.
3
Adjust R2 to 3 V ± 60 mV .
.
4
.
Connect positive lead of DVM to TP2 on PCB A7.
5
.
Cover SENSOR B14 with DENSITY TOOL PN 9191223
(ND 1.5 WRATTEN FILTER #96).
6
Adjust R1 to 3.6 V ± 72 mV.
.
KODAK AG, Stuttgart
figure 4-78
4-75
3053-3
12/1998