3053-3
2
.
Loosen SCREWS.
3
.
Adjust BRACKET to 0.3 - 0.6 mm below the BELT.
4
.
Fasten SCREWS.
CASSETTE INDUCTIVE SENSORS B28, B29
PURPOSE:
The INDUCTIVE SENSOR should recognise CASSETTES METAL EDGE.
1
.
Remove MOUNTING SCREW.
Note
Step 2, 3, 4, 5 and 6 can only be done at ML700s up to approx. SN 2200 (50 Hz) and
SN 6120 (60 Hz) where the GUIDE RING is not glued to the INDUCTIVE SENSOR.
2
.
Remove SENSOR MOUNT with INDUCTIVE SENSOR.
3
.
Loosen LOCK NUT.
4
.
Adjust GUIDE RING until it is 2.5 mm higher than the INDUCTIVE SENSOR.
12/1998
figure 4-7
4-6
ADJUSTMENTS
KODAK AG, Stuttgart