ADJUSTMENTS
ADJUSTING HUMIDIFIER PCB A16.
PURPOSE :
The HUMIDIFIER should be turned on if the relative humidity inside the ML 700 goes below
40%.The HUMIDIFIER can raise the internal humidity by approx. 20%.
Warning
Mind your head. Avoid injuries at the TUNNEL EDGES.
1
.
Separate the ML 700 from the PROCESSOR.
2
.
Take off the REAR PANEL.
Warning
BE CAREFUL. THERE ARE 220V ON THIS BOARD
3
.
Take of COVER of PCB A16.
KODAK AG, Stuttgart
REGULATOR
Connect the PRESSURE GAUGE here
figure 4-89
4-87
3053-3