REPLACEMENTS
FUNCTION TEST
1
.
Enter SERVICE MODE FDAB, Day, Day, 9.9.
2
.
Select Option 7.8.2 (VACUUM PUMPS).
3
.
Switch on VACUUM PUMP. The CASSETTE VACUUM PUMP should run for a short
moment.
4
.
Select Option 7.8.3 (CASSETTE SUCKING).
5
.
Switch on CASSETTE SUCKING. The CASSETTE VACUUM PUMP is now running.
6
.
Cover CASSETTE SUCKERS with a FILM. The VACUUM PUMP should stop.
7
.
If the CASSETTE VACUUM PUMP does not stop check for a leakage.
8
.
Switch of CASSETTE SUCKING and take out FILM.
9
.
Leave SERVICE MODE.
10
. Key in 3585 to bring all MOTORS to HOME POSITION.

REPLACEMENT TRANSPORT SHAFT ASSY

1
.
Power down ML 700.
2
.
Unplug ML 700.
3
.
To separate ML 700 from TUNNEL do the following:
Take of DRIVE BELT
Unplug TUNNEL CONNECTOR
Open QUICK DISCONNECTOR
Release TUNNEL SAFETY LOCK
Pull ML 700 away from TUNNEL
4
.
Open RIGHT and LEFT SIDE DOOR.
5
.
Take off complete TOP COVER.
6
.
Remove both VACUUM PUMPS.
KODAK AG, Stuttgart