Commissioning instructions
Audio Pack 1
The main panel and the micro Distributed amplifier unit each has an Audio pack 1 that contains the following messages and tones.
No.
Type of message
1
micro DAU Test
2
Alert
(default - Emergency 1)
3
Evacuate
(default - Emergency 2)
4
Bomb
(default - Emergency 3)
5
Alert
(alternative)
6
Evacuate
(alternative)
7
Gas Carbon Monoxide
8
Gas Fixed
Extinguishant
9
Fire alarm test
(default - Auxiliary 1)
10
Fire alarm test end
(default Auxiliary 2)
11
Coded message
12
Class change
13
Gent Limited
advertisement
14
Stand down
(default - Auxiliary 3)
15
Navy radiological attack -
16
Navy bandit attack
17
Nursery Rhyme 1
18
Nursery Rhyme 2
19
Factory test
Attention tone
No
Description of tone
1
Nee Naw x 8
2
Two tone (Bing bong)
3
Four Tones - ascending
4
Four Tones - descending
5
Bell
Voice
Message
Male
The voice alarm volumes are being adjusted there is no need to
take any action.
Female Your attention please, the fire alarm has been activated in another
area, please remain where you are and await further instructions.
Male
Attention please, attention please, this is an emergency, please
leave the building by the nearest available exit. Do not use the lifts
or escalator.
Female May I have your attention please, an incident has been reported in
the area, as a precaution please move away from the windows, I
repeat, please move away from all windows, further information
will follow shortly.
Female May I have your attention please, may I have your attention
please, an incident has been reported in the building, whilst this
report is being investigated, please remain at your workplace.
Male
Ladies and gentlemen, due to unforeseen circumstances we are
required to evacuate the building, please leave the building
immediately by the nearest available exit.
Male
May I have your attention please, may I have your attention
please, excessive carbon monoxide levels have been detected,
please leave the area immediately by the nearest available exit.
Male
May I have your attention please, may I have your attention
please, extinguishant gas release imminent, please evacuate the
area immediately by the nearest available exit.
Female Attention please, attention please, this is the test of the fire and
voice alarm system, there is no need to take any action.
Female The test of the fire and voice alarm system has now been
completed.
Female Would Mr Sands please report to reception.
Female Class change
Female Ladies and gentlemen this speech message is produced by Gent
Limited's Vigilon Compact Voice Alarm system. This product
integrates voice alarm functions into an analogue fire alarm
system ideal for small to medium sized buildings.
Female May I have your attention please, the cause of the alarm has been
investigated and the system reset. There is no cause for concern.
Thank you.
Beep beep beep (950Hz 80ms beep every 420mS)
-
Beep beep beep (950Hz 50ms beep every 80mS)
Boys & Girls
Twinkle Twinkle
-
Frequency sweep (300Hz to 10KHz in 3s)
No
6
7
8
9
10
Description of tone
Pulse
Continuous
Bong
Chopin
Jingle

Advertisement