Generic Commissioning instructions
Message
Excessive
transmission
error rate
Too many errors:
lost device or
loop split
External Fire at
panel n
Fast scan
started
number x on loop
y channel z
Fault cleared
Warning cleared
Fire number n
loop y channel z
Fire reset
Flash memory
checksum error
Full keyboard
Removed / Fitted
number x loop y
Group Enabled /
Disabled
High Error rate
at Card x
Incompatible
Card Version at
card x
Interface Failed
at Card x
Interface input
- fault /
restored
number x on
loop y channel z
Interface Input
Fire number x on
loop y channel z
Interface input
not Reset number
x on loop y
channel z
104
associated with..
meaning..
Loop Processor
There were more than 10
Card
reply errors in one day.
(More than 16 reply errors
will cause the device
isolation.)
MCC / MCB (main
There is a Fire on another
control card/board)
panel in a network.
Data logging
Fire sensor has detected a
change on its input.
MCC / MCB(main
Fault or warning has now
control card/board)
gone.
Loop Processor
Pattern match is equal to a
Card
Fire or MCP operated or
conventional detection on
IO line of interface
operated.
MCC / MCB (main
The Fire reset button has
control card/board)
been pressed.
Device
Speech Memory
Checksum Error
MCC/ MCB / DKC/
The keyboard has been
MRC
'removed' (is not fitted).
MCC / MCB (main
A group has been
control card/board)
automatically or manually
disabled or enabled.
Network
High number of
communication errors.
Any Card
There is a card software
conflict.
MCC / MCB
The interface timer chip
has failed.
Device
IO line fault.
Device
Interface IO line triggered a
fire event.
Device
The input line continues to
trigger.
..possible action
Check screening and
electrical noise in area of
operation + check loose
connections to loop.
Investigate the fire.
The message is normally
given when the data logger is
connected.
-
-
-
Replace the device
Check the cable connections
to the keyboard to bring
about the 'fitted' message.
If necessary, manually
enable/disable the group
using the [control] menu.
TBA
Fit card with compatible
software.
Clear the fault and ignore
single occurrence. Replace
the card on multiple failures.
Check the wiring and restore
the input for normal
operation.
Check the wiring and restore
the input for normal
operation.
Check devices on the IO line.
4188-856_i2_12/06_Generic Vigilon (Compact + VA) Comms.