CHAPTER 13    Network
2.
Select a port that you want to configure, and then click Edit; the following dialog box appears:
3.
Configure the port according to the parameters described in the table below.
4.
Click Apply, and then reset the device with a burn-to-flash for your settings to take effect.
Table 13-2: Physical Ports Table Parameter Descriptions
Parameter
General
'Index'
'Name'
port
[PhysicalPortsTable_
Port]
'Description'
port-
description
[PhysicalPortsTable_
PortDescription]
'Mode'
mode
[PhysicalPortsTable_
Mode]
'Speed and Duplex'
speed-duplex
[PhysicalPortsTable_
SpeedDuplex]
Ethernet Group
'Member of Ethernet
Group'
group-member
(Read-only) Displays the index number for the table row.
(Read-only) Displays the Ethernet port number. See the figure in the
beginning of this section for the mapping between the GUI port
number and the physical port on the chassis.
Defines a description of the port.
By default, the value is "User Port #<row index>".
Note: Each row must be configured with a unique name.
(Read-only) Displays the mode of the port.
[0] Disable
[1] Enable (default)
Defines the speed and duplex mode of the port.
[0] 10BaseT Half Duplex
[1] 10BaseT Full Duplex
[2] 100BaseT Half Duplex
[3] 100BaseT Full Duplex
[4] Auto Negotiation (default)
[6] 1000BaseT Half Duplex
[7] 1000BaseT Full Duplex
(Read-only) Displays the Ethernet Group to which the port belongs.
To assign the port to a different Ethernet Group, see
Ethernet Port
Groups.