CHAPTER 13    Network
'Application Type'
application-type
[InterfaceTable_
ApplicationTypes]
'Ethernet Device'
underlying-dev
[InterfaceTable_
UnderlyingDevice]
IP Address
'Interface Mode'
mode
[InterfaceTable_InterfaceMode]
'IP Address'
ip-address
[InterfaceTable_IPAddress]
Parameter
Mediant 800 Gateway & E-SBC | User's Manual
Description
The parameter value cannot contain a forward slash
(/).
Defines the applications allowed on the IP interface.
[0] OAMP = Operations, Administration, Maintenance
and Provisioning (OAMP) applications (e.g., Web,
Telnet, SSH, and SNMP).
[1] Media = Media (i.e., RTP streams of voice).
[2] Control = Call Control applications (e.g., SIP).
[3] OAMP + Media = OAMP and Media applications.
[4] OAMP + Control = OAMP and Call Control
applications.
[5] Media + Control = Media and Call Control
applications.
[6] OAMP + Media + Control = All application types
are allowed on the interface.
[99] MAINTENANCE = Only the Maintenance
application for HA is allowed on this interface.
Note:
Only one IP network interface can be configured with
OAMP in this table. To configure additional
management interfaces, see
Management
Interfaces.
Assigns an Ethernet Device to the IP interface. An
Ethernet Device is a VLAN associated with a physical
Ethernet port (Ethernet Group). To configure Ethernet
Devices, see
Configuring Underlying Ethernet
By default, no value is defined.
Note: The parameter is mandatory.
Defines the method that the interface uses to acquire its
IP address.
[3] IPv6 Manual Prefix = IPv6 manual prefix IP
address assignment. The IPv6 prefix (higher 64 bits)
is set manually while the interface ID (the lower 64
bits) is derived from the device's MAC address.
[4] IPv6 Manual = IPv6 manual IP address (128 bits)
assignment.
[10] IPv4 Manual = (Default) IPv4 manual IP address
(32 bits) assignment.
Defines the IPv4/IPv6 address in dotted-decimal
notation.
By default, no value is defined.
Note: The parameter is mandatory.