Goodrive350 series high-performance multi-function inverter
7.6.5 Unusual heating of motor
Unusual heating of the
motor
Whether the motor
parameters are set
correctly?
Whether parameter
autotuning is
performed?
No
Whether the inverter runs
at a low speed all the time?
Whether it is a variable-
frequency motor?
Whether the load is
too heavy?
Whether the three
phases of the motor are
balanced?
Whether the carrier
frequency is too low?
Whether the motor
cable is too long?
If it is an inverter fault,
contact our company
No
Yes
No
Yes
Yes
No
frequency motor
Yes
Yes
No
No
Yes
Yes
No
Yes
No
-230-
Set the motor
parameters
correctly
Parameter
autotune
Use a variable-
Reduce the
load
Replace the
motor
Set the carrier
frequency
properly
Add an output
filter
Chapter 7
Need help?
Do you have a question about the Goodrive350 Series and is the answer not in the manual?
Questions and answers