Description
Command Usages
PLOT_TIMESCALE Set
Plot Timescale
PLOT_TIMESCALE
Query
PWM Output Source
PWM#SRC Set
PWM#SRC Query
PWM High Engineering Value
PWM#ENGMAX Set
PWM#ENGMAX Query
PWM Low Engineering Value
PWM#ENGMIN Set
PWM#ENGMIN Query
PWM High Duty Cycle
PWM#DUTYMAX Set
PWM#DUTYMAX Query
PWM Low Duty Cycle
PWM#DUTYMIN Set
PWM#DUTYMIN Query
Synergy Controller Technical Manual, Revision H
Command Syntax
Range,
Units
= PLOT_TIMESCALE
ARG1: 0 - Real Time, 1 - Relative
ARG1
Time
0 - Real Time,
? PLOT_TIMESCALE
Time
Logic Function Commands
#
- A Number from 1 to 8
ARG1:
0 - Off
1 - CH1 Actual
2 - CH2 Actual
3 - CH3 Actual
4 - CH1 Setpoint
5 - CH2 Setpoint
6 - CH3 Setpoint
7 - CH1 Heat PID
8 - CH1 Cool PID
9 - CH2 Heat PID
10 - CH2 Cool PID
11 - CH3 Heat PID
12 - CH3 Cool PID
13 - CH1 Cascade Air
14 - CH2 Cascade Air
15 - CH3 Cascade Air
16 - CH1 Full PID
17 CH2 Full PID
= PWM#SRC ARG1
18 - CH3 Full PID
? PWM#SRC
0 - 18
#
- A Number from 1 to 8
ARG1: -200 - 5000
= PWM#ENGMAX ARG1
? PWM#ENGMAX
-200 to 5000
#
- A Number from 1 to 8
ARG1: -200 - 5000
= PWM#ENGMIN ARG1
? PWM#ENGMIN
-200 to 5000
#
- A Number from 1 to 8
= PWM#DUTYMAX ARG1
ARG1: 0% - 100%
? PWM#DUTYMAX
0% - 100%
#
- A Number from 1 to 8
= PWM#DUTYMIN ARG1
ARG1: 0% - 100%
? PWM#DUTYMIN
0% - 100%
Command
Example
= PLOT_TIMESCALE 1
1 - Relative
? PLOT_TIMESCALE
= PWM1SRC 1
? PWM1SRC
= PWM1ENGMAX 200
? PWM1ENGMAX
= PWM1ENGMIN -100
? PWM1ENGMIN
= PWM1DUTYMAX 95
? PWM1DUTYMAX
= PWM1DUTYMIN 5
? PWM1DUTYMIN
Response Example
OK
1
OK
1
OK
200
OK
-100
OK
95
OK
5
Page 266