Chapter 2 - Installation
3. The IF cable connector should be sealed properly to protect against
rain and moisture.
4. Route the cable to the location selected for the indoor equipment.
Connecting the SU's IDU-ODU Cable
CAUTION
Use only Category 5E 4x2x24# FTP outdoor cables from an approved manufacturer.
See list of approved cables in Table 2-3 on page 2-6.
To connect the IDU-ODU cable:
1. Remove the two screws holding the waterproof service box to the
outdoor unit and remove the service box.
2. Unscrew the top nut from the service box.
3. Route a straight, uncrimped Cat. 5E Ethernet cable (8-wire, 24
AWG) through both the top nut and the body of the service box.
4. Insert and crimp the RJ-45 connector. Refer to
instructions on preparing the cable.
5. Connect the Ethernet cable to the IDU COM RJ-45 connector.
6. Replace the service box and then tighten the top nut. Make sure
that the external jack of the cable is well inside the service box to
guarantee a good seal.
7. Route the cable to the location selected for the indoor equipment.
8. Assemble an RJ-45 connector with a protective cover on the indoor
end of the IDU-ODU cable.
NOTE
The length of the Indoor-to-Outdoor cable, together with the length of the Ethernet cable
connecting the CPE-IDU-1D to the data equipment, should not exceed 100 meters.
2-12
Appendix A
for
BreezeMAX System Manual