Table 3-8: Micro Base Station Leds - Alvarion BreezeMAX 3500 System Manual

Hide thumbs Also See for BreezeMAX 3500:
Table of Contents

Advertisement

Chapter 3 - Commissioning
Micro Base Station LEDs
To verify the correct operation of the Micro Base Station equipment,
examine the LED indicators located on the front panel of the unit. The
following table lists the LEDs of the Micro Base Station and their
associated indications.
Name
Description
PWR
Power indication
ALRM
Micro Base Station alarm
indication
SP
Spare
EXT ALRM
External alarm indication
WACT
Wireless link activity
indication
WLINK
Wireless link status
indication
ODU 1/ODU 2
ODU power indication
PWR
ODU 1/ODU 2
ODU alarm indication
ALRM
3-8

Table 3-8: Micro Base Station LEDs

Functionality
Red – Micro Base station failure
Not Used
Red – External alarm (received via the
ALRM IN port). Not applicable in current
release.
IDU-ODU communication failure
Off – Micro Base Station is not
powered
Red – Input power failure
Green – Micro Base Station power OK
Off – No wireless link activity
Green (blinking) – Wireless link
activity
Off – No SU is connected
Green – At least one SU is connected
Off – ODU not powered
Red – ODU power (-48VDC) failed
Green – ODU power OK
BreezeMAX System Manual

Advertisement

Table of Contents
loading

Table of Contents