Chapter 3 - Commissioning

SU Commissioning

Configuring Basic Parameters in SUs
After completing the installation process, as described in the preceding
chapter, the basic parameters must be configured to ensure that the
unit operates correctly and can communicate with the AU. Once the
basic parameters have been configured, additional parameters can be
remotely configured via the wireless link.
To configure the SU's basic parameters:
1. Connect a PC to the Ethernet port, using a crossed cable.
2. Configure the PC's IP parameters to enable connectivity with the
unit. The IP address of the Monitor program port is
192.168.254.251. The Subnet Mask is 255.255.255.0. The
recommended IP address for the PC is 192.168.254.250, since this
is also the default TFTP Sever IP Address (required for downloading
SW versions and for downloading/uploading configuration files)
3. Run the Telnet program connecting to 192.168.254.251. The Enter
the passwod prompt is displayed. Enter the password and press the
Enter key.
NOTE
The default password is "installer".
4. The Main menu of the SU Installer Monitor program is displayed,
enabling you to access the required parameters configuration and
performance monitoring options. Refer to
instructions on using the SU Installer Monitor program and detailed
information on the various parameters and other features supported
by the program.
5. Configure the basic parameters listed in Table 3-9 on page 3-11.
6. Reset the unit to enable synchronization with the AU.
3-10
Appendix B
for
BreezeMAX System Manual